Heaters |
 |
|
|
|
|
The new EDENPAC heat pumps offer an
efficient solution for the heating of outdoor pools from 50 to 160 m3. Easy to use thanks to the
digital control thermostat, you simply read and
select the exact pool temperature required. Discrete
and silent, EDENPAC heat pumps are equipped
with a high-yield SCROLL compressor. Equipped
with a flow controller, the EDENPAC heat pump
starts and stops automatically at the same time as
the filter system.
A titanium water condenser unit offers a life-long
guarantee against corrosion.
In compliance with EC standards.
Refrigerant R410A (in compliance with valid
refrigerant legislation).
|
|
| Model |
EDENPAC 1 |
EDENPAC 2 |
EDENPAC 3 mono |
EDENPAC 3 tri |
EDENPAC 4 |
EDENPAC 5 |
| Power restored at 15°C outside temp. (kW) |
8,5 |
10 |
12 |
12 |
15 |
16 |
| Power consumed at 15°C outside temp. (kW) |
1,8 |
2,04 |
2,42 |
2,46 |
3,15 |
3,22 |
| COP (Power restored/power consumed) |
3,22 |
4,89 |
4,96 |
4,88 |
4,76 |
4,97 |
| Max. pool volume (m3) |
0 à 55 |
45 à 70 |
60 à 85 |
60 à 85 |
75 à 110 |
100 à 120 |
| Average water flow-rate (m3/h) |
5 |
5 |
5 |
5 |
6,5 |
6,5 |
| Head loss (mCE) |
1,3 |
1,3 |
1,3 |
1,3 |
1,7 |
1,7 |
| Hydraulic connections |
PVC 1/2 unions Ø 50 to glue |
| Electrical power supply |
230 V/50 Hz |
230 V/50 Hz |
230 V/50 Hz |
400 V/50 Hz |
230 V/50 Hz |
400 V/50 Hz |
| Rated current consumption (A) |
8,5 |
9,8 |
13 |
5,8 |
20 |
6 |
| Max. current consumption (A) |
13 |
15 |
16 |
7 |
23 |
9 |
| Acoustic power (dBa)** |
65,5 |
66,5 |
66,5 |
66,5 |
67,4 |
70 |
| Acoustic power at 10 m (dBa)** |
37,5 |
38,5 |
38,5 |
38,5 |
39,4 |
42 |
| Weight (kg) |
86 |
87 |
90 |
90 |
99 |
99 |
|
|
** Values measured and certified compliant with EN ISO 3741 and EN ISO 354 standards by CTTM (Le Mans Technology Transfer Centre) |
|
A 104 mm Edenpac 6
657 mm Edenpac 7-8
B 488 mm Edenpac 6
1041 mm Edenpac 7-8 |
| Model |
EDENPAC 6 |
EDENPAC 7 |
EDENPAC 8 |
| Power restored at 15°C outside temp. (kW) |
21 |
24 |
28 |
| Power consumed at 15°C outside temp. (kW) |
4,02 |
5 |
5,6 |
| COP (Power restored/power consumed) |
4,02 |
4,8 |
5,0 |
| Max. pool volume (m3) |
110 à 150 |
100 à 180 |
140 à 200 |
| Average water flow-rate (m3/h) |
7,5 |
7,5 |
7,5 |
| Head loss (mCE) |
1,1 |
1,1 |
1,1 |
| Hydraulic connections |
PVC 1/2 unions Ø 50 to glue |
| Electrical power supply |
400 V/50 Hz |
230 V/50 Hz |
400 V/50 Hz |
| Rated current consumption (A) |
7 |
24,6 |
10,4 |
| Max. current consumption (A) |
11 |
32 |
16 |
| Acoustic power (dBa)** |
71,5 |
70 |
*** |
| Acoustic power at 10 m (dBa)** |
43,5 |
42 |
*** |
| Weight (kg) |
130 |
165 |
150 |
|
** Values measured and certified compliant with EN ISO 3741 and EN ISO 354 standards by CTTM (Le Mans Technology Transfer Centre)
|
|
|
|